Transformation Efficiency in CFU/µg: The Calculation and What It Hides
7 min read · Updated November 11, 2026
Transformation efficiency is the number that tells you whether a failed cloning experiment failed at the transformation step. It is reported in colony-forming units per microgram of DNA, and the arithmetic takes about a minute.
What takes longer is knowing whether the number you got is good. That depends on the DNA amount and on the method, and comparing two efficiencies measured differently is how a perfectly healthy prep looks broken.
The formula
Efficiency (CFU/µg) = colonies counted × (total recovery volume ÷ volume plated) × dilution factor ÷ DNA mass in µg. Every term is there because a plate is a sample of a sample: you transformed some DNA, recovered the cells into a volume, plated part of it, and possibly diluted that part first.
The DNA mass must be in micrograms. A typical experiment uses 1 to 100 ng, which is 0.001 to 0.1 µg, and forgetting that conversion inflates the answer by a thousand.
Worked: 250 colonies from 100 pg
Transform 100 pg of a 3 kb plasmid, recover into 1,000 µL, plate 100 µL of a 1:10 dilution, and count 250 colonies. The plated fraction is 100 ÷ 1,000 = 0.1, and the dilution adds a factor of 10, so the plate represents 1/100 of the transformation. The DNA is 100 pg = 0.0001 µg.
Efficiency = 250 × 10 × 10 ÷ 0.0001 = 2.5 × 10⁸ CFU/µg. That is a good chemically competent prep, in the range a commercial preparation sold at 5 × 10⁸ CFU/µg is meant to deliver.
A second worked case, the way a teaching lab usually does it: 50 pg of DNA, 500 µL recovery, 100 µL plated, 200 colonies. The plated fraction is 0.2, so efficiency = 200 × 5 ÷ 0.00005 = 2.0 × 10⁷ CFU/µg. That is an order of magnitude lower — 12.5×, not the same number measured twice — and it is explained entirely by the smaller recovery volume and the lower DNA amount rather than by weaker cells.
What the number should look like
Chemically competent cells made in a lab typically land between 10⁶ and 10⁸ CFU/µg, with good preps around 10⁸. Electrocompetent cells run about a thousand-fold higher, 10⁹ to 10¹⁰ CFU/µg, which is why electroporation is used when the DNA is limiting — a library, or a ligation with almost no product.
A number below 10⁶ from a protocol that should give 10⁸ is not a marginal result, it is a failed step. The causes are a short heat shock, cells thawed and refrozen, a recovery period that was too short, or a plate whose antibiotic concentration is wrong.
The figure you should compare against is one you measured yourself on the same cells with a known intact plasmid. Published numbers are for someone else's cells, someone else's DNA and someone else's definition of a colony.
Why more DNA is not more efficiency
Efficiency is per microgram, so it is meant to be independent of how much you used. It is not, at the top end: transform a microgram instead of a nanogram and the colony count saturates, because the number of competent cells in the tube becomes the limit rather than the amount of DNA. Compute the efficiency from that plate and it comes out lower, for a reason that has nothing to do with the cells.
The practical consequence is to keep the DNA in the linear range — tens of nanograms for a plasmid, less for a ligation — and to trust the efficiency figure only from a plate where the colonies are countable and well separated.
What the number does not measure
- Whether the plasmid is the right one. Efficiency counts colonies, and a contaminating plasmid transforms just as well.
- Whether the insert is present. A recircularised empty vector is a colony like any other, which is what the unligated-vector control is for.
- Whether the cells are still competent now. Efficiency measured last month is a property of that batch and that freeze-thaw history.
- Whether the transformation is the limiting step in your experiment. A blank plate with a good efficiency figure points at the ligation or the construct, not the cells.
FAQ
How do I calculate transformation efficiency in CFU/µg?
Colonies × (recovery volume ÷ volume plated) × dilution ÷ DNA in µg. For example, 250 colonies from 100 pg plated as 100 µL of a 1:10 dilution from 1,000 µL gives 250 × 10 × 10 ÷ 0.0001 = 2.5 × 10⁸ CFU/µg.
What is a good transformation efficiency?
Around 10⁸ CFU/µg for good chemically competent cells, and 10⁹ to 10¹⁰ for electrocompetent cells. Below 10⁶ from a protocol that should reach 10⁸ indicates a failed step rather than a weak result.
Why does my efficiency drop when I use more DNA?
Because the colony count saturates when competent cells rather than DNA become limiting. Efficiency is defined per microgram, so a saturated plate computes a lower figure even though the transformation worked.
Does a high transformation efficiency mean my cloning worked?
No. It means the cells took up DNA and grew. It says nothing about whether that DNA carries the insert, which is what the unligated-vector control and a colony PCR or digest are for.
Related references
Related tools
Diagnosis of no-colony, empty-vector and missing-band outcomes from design and control plates.
Gibson, Golden Gate and restriction cloning: fragment assembly and junction primers.
309 public vectors with full GenBank feature tables, and 617 parts extracted from them.
Mass, moles, molarity and copy number conversion for DNA and RNA.